DRV8832

$
0
0

Would you tell me about these questions?

1) How long time does it take to become "FAULTn = Low" after OCP is worked?

We suppose a process below;

1. Output current of over 1.3A continue about 275ms.
|
2. DRV8832 detect OCP
|
(I would like to ask you the necessary time between 2. and 3.)
|
3. FAULTn become to Low.

2) After FAULTn becomes low, how long time should I set IN1 and IN2 low to enable DRV8832?

  I understand there are 2 methods with VCC and IN1/IN2 to enable DRV8832.

Best regards,
Y.Hirata